- Self-consumption and feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
- Built-in Timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real time status display and control
- Custom-made firmware by ODM contract
- Parallel operation up to 6 units
| Specification | InfiniSolar 3P 15KW |
|---|---|
| Phase | 3-phase in / 3-phase out |
| Maximum PV Input Power | 22500 W |
| Rated Output Power | 15000 W |
| Maximum Charging Power | 15000 W |
| Grid-Tie Operation | |
| PV Input (DC) | |
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC |
| MPP Voltage Range | 400 VDC ~ 800 VDC |
| Number of MPP Trackers / Maximum Input Current | 2 / A: 37.65A; B: 18.6A |
| Grid Output (AC) | |
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
| Output Voltage Range | 184 – 264.5VAC per phase |
| Nominal Output Current | 21.7A per phase |
| Power Factor | > 0.99 |
| Efficiency | |
| Maximum Conversion Efficiency (DC/AC) | 96% |
| European Efficiency @ Vnominal | 95% |
| Off-Grid Operation | |
| AC Input | |
| AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC per phase / 180 VAC per phase |
| Acceptable Input Voltage Range | 170 – 280 VAC per phase |
| Maximum AC Input Current | 40 A |
| PV Input (DC) | |
| Maximum DC Voltage | 900 VDC |
| MPP Voltage Range | 350 VDC ~ 850 VDC |
| Number of MPP Trackers / Maximum Input Current | 2 / A: 37.65A; B: 18.6A |
| Battery Mode Output (AC) | |
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
| Output Waveform | Pure Sinewave |
| Efficiency (DC to AC) | 91% |
| Hybrid Operation | |
| PV Input (DC) | |
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC |
| MPP Voltage Range | 350 VDC ~ 850 VDC |
| Number of MPP Trackers / Maximum Input Current | 2 / A: 37.65A; B: 18.6A |
| Grid Output (AC) | |
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
| Output Voltage Range | 184 – 264.5 VAC per phase |
| Nominal Output Current | 21.7 A per phase |
| AC Input | |
| AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC per phase / 180 VAC per phase |
| Acceptable Input Voltage Range | 170 – 280 VAC per phase |
| Maximum AC Input Current | 40 A |
| Battery Mode Output (AC) | |
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
| Efficiency (DC to AC) | 91% |
| Battery & Charger | |
| Nominal DC Voltage | 48 VDC |
| Maximum Charging Current | Default 60A, 5A – 300A (Adjustable) |
| General | |
| Physical | |
| Dimension, D x W x H (mm) | 219 x 650 x 820 |
| Net Weight (kgs) | 62 |
| Interface | |
| Communication Port | RS-232, USB and Dry contact |
| Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
| Environment | |
| Humidity | 0 ~ 90% RH (Non-Condensing) |
| Operating Temperature | -10 to 55°C |
| Altitude |